Sign In | Join Free | My udpf.com
China Jufu Water Technology Co., Ltd logo
Jufu Water Technology Co., Ltd
Water Treatment Equipment Expert Worldwide!
Active Member

3 Years

Home > RO Water Treatment System >

2.2KW Reverse Osmosis Water System Treatment Plant 1000Lph

Jufu Water Technology Co., Ltd
Contact Now

2.2KW Reverse Osmosis Water System Treatment Plant 1000Lph

Brand Name : Jufu

Model Number : JFRO-1000L

Certification : ISO9001

Place of Origin : China

MOQ : 1 unit

Price : Negotiable

Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram

Delivery Time : 2-4 weeks

Packaging Details : Export standard wooden box (like plywood), no need to fumigate, really suitable for shipping.

Host Size : 1000x600x1600mm (can be customized)

Power : 2.2KW

Power Supply : 220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized

Operating Pressure : 0.8-1.2MPa

Designed Water Inlet : 2000L/h

Outlet Flow : 1000L/h

Desalination rate : ≥99.5%

Raw Water Pump : CNP/NYP/GRUNDFOS (Optional)

Membrane size : 4040

Number of Membranes : 4

Membrane elements : DOW/Hydranautics/Troy/Vontron (optional)

Control valve : Manual/Automatic

Control Valve Brand : FLECK/RUNXIN

Tank Material : SS/FRP (Optional)

Pipe Material : U-PVC, Stainless steel (Optional)

Contact Now

Reverse Osmosis Ro Water System Treatment Plant 1000 Lph

Product Introduction of RO Water Treatment System

The device’s key part is reverse osmosis membranes that is from America, it has a good performance to eliminate salts and the high-pressure pump is from a high-quality pump producer in China, it is easy to handle for its simple structure. The source water, in the case that the TDS is less than 400mg/L, can reach the national standards totally after treatment by this device, it is the most ideal equipment for water treatment.
The reverse osmosis can remove more than 97% of the soluble salt and above 99% of the colloid, microorganism, particles and rganic materials, becoming the best first-choice equipment in the engineering of modern purified water, highly purified water and space water (super-purified water). The most highlighted features are low energy consumption, no pollution, simple technique, high-quality water and convenient operation and maintainable.
Stainless-steel high-pressure shell.
All kinds of capacity indicator, pressure indicator, electricity magnetic valve, balance device and pipe valve system.
Online type pressure auto self-protection device.
Online type of electricity indicator (with stable compensation).
System safe protecting and alarm system.

The Basic Working Principle of RO Water Treatment System
After a special high-pressure pump, when the raw water is added to a pressure of 6-20 kg, the raw water permeates through the reverse osmosis membrane with a pore size of only 0.0001 microns under the action of pressure. Chemical ions, bacteria, fungi, and virions cannot pass through, and are discharged with wastewater. Only water molecules and solvents with a volume of less than 0.0001 microns are allowed to pass through.

Technical Specifications of RO Water Treatment System

1000LPH Reverse Osmosis System
Model JFRO-1000L
Host Size

1000x600x1600mm (can be customized)

Power 2.2KW
Power Supply

220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized

Operating Pressure 0.8-1.2MPa
Recovery Rate 50%
Designed Water Inlet 2000L/h
Outlet Flow 1000L/h
Desalination Rate ≥99.5%
RO Frame SUS304
Membrane Size 4040
Membrane Elements DOW /Hydranautics/Troy/ Vontron (Optional)
Number of Membranes 4
Raw Water Pump CNP/NYP/GRUNDFOS (Optional)
Raw Water Pump CNP/NYP/GRUNDFOS (Optional)
Tank Material SS/FRP (Optional)
Control Valve Manual/Automatic
Control Valve Brand FLECK/RUNXIN
Membrane Housing SS/FRP (Optional)
Pipe Material U-PVC, Stainless steel (Optional)


























Advantages of RO water treatment system:
Reverse osmosis equipment belongs to physical desalting method, which has many advantages.
1) Non-phase-change physical method was used to desalinate and purify the saline water under norma temperature.
2) Desalting rate of single membrane element is 99.3% and can remove colloid, organics, bacteria, virus and all kinds of heavy metals in water at the same time.
3) With water pressure as the driving force, energy consumption is the lowest among many treatment methods.
4) No need for large amount of chemical treatment, no elimination of chemical waste liquid, no environmental pollution, and the recovery rate is over 70%.
5) High automation program, automatic stop in case of ailure, with automatic protection function.
6) The system is simple, easy to operate, and the water quality is stable.
7) Equipment covers small area, compact structure, reliable operation and high water quality.

Process flow of RO Water Treatment System
Raw water → Raw water tank → Raw water pump → Multi-media filter (quartz sand filter) → Activated carbon filter → Soft water processor → Precision filter → High pressure pump → Primary reverse osmosis (RO) device → Purified water tank → High pressure pump → Two Stage reverse osmosis → ultraviolet sterilization device → water point.

2.2KW Reverse Osmosis Water System Treatment Plant 1000Lph

Photos of Reverse Osmosis Water Treatment System
2.2KW Reverse Osmosis Water System Treatment Plant 1000Lph
2.2KW Reverse Osmosis Water System Treatment Plant 1000Lph
Demonstration of the application of reverse osmosis system
2.2KW Reverse Osmosis Water System Treatment Plant 1000Lph
Replacement of consumables
2.2KW Reverse Osmosis Water System Treatment Plant 1000Lph
Products you may be interested in
2.2KW Reverse Osmosis Water System Treatment Plant 1000Lph

2.2KW Reverse Osmosis Water System Treatment Plant 1000Lph
2.2KW Reverse Osmosis Water System Treatment Plant 1000Lph

2.2KW Reverse Osmosis Water System Treatment Plant 1000Lph

2.2KW Reverse Osmosis Water System Treatment Plant 1000Lph

2.2KW Reverse Osmosis Water System Treatment Plant 1000Lph

2.2KW Reverse Osmosis Water System Treatment Plant 1000Lph

FAQ:

1. What is the design water yield of ro membrane element? (except anti-pollution membrane and seawater desalination membrane)

Model 4040 is designed by 0.25m3/h

Model 8040 is designed by 1-1.2m3/h

2. What is the material of mechanical filter?

Carbon steel, stainless steel, fiberglass

3.What are the multi-way control valves?

Manual control valve, automatic control valve

Multi - way control valve is divided into: filter valve and softening valve

Automatic control valve is divided into: time type and flow type.

Multi-way control valve brands are: FLECK, AUTOTROL, Runxin, clean source, etc.


Product Tags:

2.2KW RO Water Treatment Plant

      

1000Lph Reverse Osmosis Water System

      

FRP Membrane Housing Water Treatment System

      
Best 2.2KW Reverse Osmosis Water System Treatment Plant 1000Lph wholesale

2.2KW Reverse Osmosis Water System Treatment Plant 1000Lph Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Jufu Water Technology Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)